Resultado da pesquisa (2)

Termo utilizado na pesquisa Sanches M.P.

#1 - Abdominal B-mode and Doppler ultrasonography of chemically restrained agouti (Dasyprocta prymnolopha Wagler, 1831)

Abstract in English:

Agoutis are small-sized wild animals whose body weight can reach up to 4kg, and are found throughout Brazil. They are considered important seed dispersers, especially for big trees and there are species that rely almost exclusively on these animals for their territorial distribution. The objective of the present study was B scan and Doppler ultrasound characterization of the abdominal organs of healthy agoutis reared in captivity. Fifteen agoutis, chemically restrained, were used from the Nucleus for Wild Animal Studies and Conservation (Núcleo de Estudos e Preservação de Animais Silvestres - NEPAS), CCA-UFPI, submitted to B scan and Doppler ultrasound examination. The urinary bladder wall was hyperechogenic, thin, smooth and regular throughout its anatomic path, with 0.09±0.03cm mean thickness. The kidneys showed fine and homogeneous echotexture, preserved global echogenicity, hyperechogenic in relation to the spleen and isoechogenic or discreetly hyperechogenic in relation to the liver. The spectral Doppler trace showed systolic and diastolic peaks, wide and thread-like, with low flow resistance and a continuous and full diastolic portion that decreased gradually during the diastole (75.83±1.42cm/s, for the right kidney and 80.43±1.22cm/s, for the left kidney). The right adrenal gland was 0.61-1.18cm long and 0.17-0.32cm in diameter, while the left adrenal gland was 0.62-1.16 long with 0.14-0.25cm diameter. The agouti spleen was filiform in shape, with pointed poles and 1.02±0.18cm in diameter. The agouti liver occupied all the abdominal cavity cranial space in direct contact with the diaphragm. The intrahepatic vascular flow allowed individualization of the portal vein (PV) and hepatic vein (HV). The portal veins were distinguished from the hepatic veins mainly by their wall echogenic pattern. The pancreas was 0.51±0.1 cm thick and the pancreatic duct measured 0.12±0.02cm. The stomach was placed to the left the spleen and to the right of the proximal intestine and the transversal colon and the walls were 0.16±0.05cm thick. The abdominal aorta was 0.43±0.04cm in diameter and showed 95.2±2.16cm/s vascular flow. This study characterized agouti organs and abdominal blood vessels by B scan and Doppler ultrasound, that permitted definition of the size, shape, position, echogenicity and echotexture of the anatomic constituents and established reference values for the vascular network and blood flow in the species.

Abstract in Portuguese:

As cutias são animais silvestres de pequeno porte, cujo peso corpóreo pode chegar até 4kg, e existem em todo território brasileiro. São considerados importantes dispersores de sementes, especialmente para árvores de grande porte, existindo espécies que dependem quase que exclusivamente destas para sua distribuição territorial. Este trabalho teve por objetivo a caracterização ultrassonográfica modo B e Doppler dos órgãos abdominais de cutias hígidas criadas em cativeiro. Foram utilizadas 15 cutias, contidas quimicamente, oriundas do Núcleo de Estudos e Preservação de Animais Silvestres – NEPAS, CCA-UFPI, submetidas a exame ultrassonográfico em modo B e Doppler. A parede da vesícula urinária presentou-se hiperecogênica, fina, lisa e regular em todo seu trajeto anatômico, com espessura média de 0,09±0,03cm. Os rins demonstraram ecotextura fina e homogênea, ecogenicidade global preservada, hipoecogênico em relação ao baço e isoecogênico ou discretamente hipoecogênico em relação ao fígado. O traçado em Doppler espectral mostrou pico sistólico e diastólico, amplo e afilado, exibindo baixa resistência de fluxo, com uma porção diastólica contínua e cheia, que diminui gradativamente no decorrer da diástole (75,83±1,42cm/s para o rim direito e 80,43±1,22 cm/s para o esquerdo. A adrenal direita apresentou uma variação de comprimento entre 0,61 a 1,18cm e diâmetro variando entre 0,17 a 0,32cm, enquanto a adrenal esquerda evidenciou comprimento de 0,62 a 1,16 e diâmetro de 0,14 a 0,25cm. O baço das cutias mostrou formato filiforme, com polos pontiagudos e diâmetro de 1,02±0,18cm. O fígado da cutia ocupa todo o espaço cranial da cavidade abdominal, em contato direto com o diafragma. O fluxo vascular intrahepático permitiu individualizar as veias porta (VP) e veias hepáticas (VH). As veias porta foram distinguidas, particularmente pelo padrão ecogênico de suas paredes, quando comparadas com as veias hepáticas. A espessura do pâncreas foi de 0,51±0,1cm e o ducto pancreático mediu 0,12±0,02cm. O estômago relaciona-se à esquerda com o baço e a direita com o duodeno proximal e colón transverso. Sua espessura de parede mensurada foi de 0,16±0,05cm. A aorta abdominal possui diâmetro de 0,43±0,04cm e fluxo vascular de 95,2±2,16cm/s. Este estudo caracterizou os órgãos e vasos sanguíneos abdominais de cutias, por meio de ultrassonografia modo B e Doppler, o que permitiu definir o tamanho, formato, posição, ecogenicidade, ecotextura dos constituintes anatômicos, além de estabelecer valores de referência para a rede vascular e fluxo sanguíneo na espécie.


#2 - Computerized electrocardiogram in agoutis (Dasyprocta prymnolopha Wagler, 1831) anesthetized with ketamine and midazolam, 37(2):150-155

Abstract in English:

ABSTRACT.- Diniz A.N., Pessoa G.T., Moura L.S., Sanches M.P., Rodrigues R.P.S., Sousa F.C.A., Ambrósio C.E. & Alves F.R. 2017. Computerized electrocardiogram in agoutis (Dasyprocta prymnolopha Wagler, 1831) anesthetized with ketamine and midazolam. Pesquisa Veterinária Brasileira 37(2):150-155. Departamento de Morfofisiologia Veterinária, Universidade Federal do Piauí, Campus Universitário Ministro Petrônio Portela, Bairro Ininga, Teresina, PI 64049-550, Brazil. E-mail: flavioribeiro@ufpi.edu.br An electrocardiogram is a test that assesses heart electrical activity and is applied more frequently in the veterinary care of wild animals. The present study aimed to define the electrocardiogram pattern of agoutis (Dasyprocta prymnolopha Wagler, 1831) anesthetized with ketamine and midazolam. Eighteen clinically healthy agoutis (D. prymnolopha) were used from the Nucleus for Wild Animal Studies and Conservation (NEPAS) of the Federal University of Piauí, Brazil. The animals were chemically restrained with 5% ketamine hydrochloride at a dose of 15mg/kg and midazolam at a dose of 1mg/kg by intramuscular injection. Electrocardiogram tests were carried out by a computerized method with the veterinary electrocardiogram [Acquisition Model for Computer (ECG - PC version Windows 95) Brazilian Electronic Technology (TEB) consisting of an electronic circuit externally connected to a notebook computer with ECGPC-VET (TEB) software installed on the hard disc. In analysing the EKG results, significant differences were observed for QRS complex duration, PR and QT intervals and for R wave millivoltage between the genders; but we observed a significant influence of weight despite the gender. In the present experiment, the anaesthetic protocol was shown to be well tolerated by the agoutis, and no arrhythmias occurred during the time the animals were monitored. The reference values obtained should be used to better understand the cardiac electrophysiology of the species and for its clinical and surgical management.

Abstract in Portuguese:

RESUMO.- Diniz A.N., Pessoa G.T., Moura L.S., Sanches M.P., Rodrigues R.P.S., Sousa F.C.A., Ambrósio C.E. & Alves F.R. 2017. Computerized electrocardiogram in agoutis (Dasyprocta prymnolopha Wagler, 1831) anesthetized with ketamine and midazolam. Pesquisa Veterinária Brasileira 37(2):150-155. Departamento de Morfofisiologia Veterinária, Universidade Federal do Piauí, Campus Universitário Ministro Petrônio Portela, Bairro Ininga, Teresina, PI 64049-550, Brazil. E-mail: flavioribeiro@ufpi.edu.br O eletrocardiograma computadorizado é um dos meios de diagnóstico utilizado para avaliação do coração e vem sendo cada vez mais presente na rotina veterinária. Este trabalho teve por objetivo definir o padrão eletrocardiográfico de cutias (D. prymnolopha) anestesiadas com cetamina e midazolam. Foram utilizadas 18 cutias clinicamente saudáveis, provenientes do Núcleo de Estudos e Preservação de Animais Silvestres (NEPAS) da Universidade Federal do Piauí. Os animais foram submetidos à contenção química com cloridrato de cetamina a 5% na dosagem de 15mg/kg associado ao midazolam, na dosagem de 1mg/kg, por via intramuscular. Os exames eletrocardiográficos foram realizados pelo método computadorizado, com o eletrocardiógrafo veterinário (Módulo de Aquisição de ECG Para Computador (ECG - PC versão Windows 95) Tecnologia Eletrônica Brasileira (TEB) composto por um circuito eletrônico ligado externamente a um notebook, e de um software instalado no disco rígido do computador. Os valores de duração do complexo QRS, intervalos PR e QT, comparados entre machos e fêmeas, apresentaram diferença significativa. Em milivoltagem a onda R foi o único parâmetro que apresentou diferença significativa entre machos e fêmeas. O peso dos animais também foi significativamente diferente entre os gêneros. O protocolo anestésico mostrou-se bem tolerado pelos animais deste experimento, não ocorrendo quadros de arritmias durante o tempo de monitoramento dos animais.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV